From the Vault to the Bench - a Tek scope that seems to need some calibration. Let's take a look!
Join Team FranLab!!!! Become a patron and help support my YouTube Channel on Patreon: http://www.patreon.com/frantone
#franlab #oscilloscope #Tek
- Music by Fran Blanche -
Fran on Twitter - https://twitter.com/contourcorsets
Fran's Science Blog - http://www.frantone.com/designwritings/design_writings.html
FranArt Website - http://www.contourcorsets.com

By Fran

12 thoughts on “Tektronix tds 2022 scope teardown”
  1. Avataaar/Circle Created with python_avatars dentakuweb says:

    If your probe is set to 10X you have to set the scope to 10X and the same for 1X (which I never use).
    If the probe and scope aren't set the same way you will be orders of magnitude off.

    Fancy scopes have probes that tell the scope if you're using 1X, 10X etc. probes but that little Tek relies on the user setting everything up themselves.

  2. Avataaar/Circle Created with python_avatars dyno mike says:

    That was Frantastic

  3. Avataaar/Circle Created with python_avatars Davy Oneness says:

    You have your scope probes setup wrong in the scope settings. When they calibrate them, they connect in where you pulled the back cover off with the cal sticker on it. All the cal adjustments done digital because the pots are digital inside the ICs. Its mostly automated now a days.

  4. Avataaar/Circle Created with python_avatars gabest4 says:

    I think it's the Russian knockoff Tektronjx. Or my eyesight is going bad.

  5. Avataaar/Circle Created with python_avatars 0neIntangible says:

    I was expecting to come across at least one tamper resistant screw head, just to screw things up… but alas… btw, scope; free… replacement calibration stickers; $27 ea.

  6. Avataaar/Circle Created with python_avatars boredgrass says:

    The FranLab label was a lovely idea!

  7. Avataaar/Circle Created with python_avatars Paweł Osiński says:

    Lower port is a IEE-488 known as GPIB or HP-IB measure data exchange port – Very useful for measure automation. Tektronix oscilloscopes series 2xxx was last with passive LCD screen. You should check attenuator settigs in channels menu. Probably input attenuator is on, I remeber the same in TDS210 model.

  8. Avataaar/Circle Created with python_avatars Tristian Corbett says:

    Is the little button at the top right of screen with a slit on it the brightness control

  9. Avataaar/Circle Created with python_avatars robert meyer says:

    That a great scope. I think you can download a manual for that. I got a old tube type one. nothing that new except a PC scope. just a black box with 4 BNC and USB port. works super great. I love the old heat kit test equipment most of mine has nixie displays . my B and K and fluke has VFD. once you figure that scope out it will be a lot of fun. Thay make a USB to RS232 converter and just find drivers and you can bring it to a PC. love that barcode on top. I have outher newer test equipment spectrum analyzer ETC. my 4 channel PC scope works so good and does so much . The gift back will be using it .

  10. Avataaar/Circle Created with python_avatars Gregory Thomas says:

    What an awesome score! Big thanks to the donator 🙂

  11. Avataaar/Circle Created with python_avatars Jessica V says:

    Bundles of wires resting up against the sharp edge of sheet metal? Nice.

  12. Avataaar/Circle Created with python_avatars Zed Carr says:

    If you only do audio, a CRO is the way to go. IMHO.